Washtec is available in single size pot (P) or duel size pot (PA2) options, allowing you to choose the best configuration for your testing requirements. Washtec PA2 has been exclusively designed to allow the user to utilise equal numbers of 550ml (ISO) pots and 1200ml (AATCC) pots.
TEST METHODS
AATCC :AATCC 2, 3, 28, 61, 151, 190 AATCC 86, 132, 151.
ISO :ISO 105-C06,ISO 105-C08,ISO 105-C09,ISO 105-C10,ISO 105-D01,ISO 105-E03.
M&S :M&S C04, M&S C05, M&S C10A, M&S C37, M&S P12A.
WOOLMARK :TM 7, TM 115, TM 177, TM 193, TM 199, TM 240, TM241.
NEXT :TM 2 / 2A , TM 3 / 3A, TM 5.
Ancillary equipment and consumables conforming to major international standards and Brand requirements can be supplied on request.
FORM Constructed from high grade stainless steel for long life, the Washtec incorporates a number of safety and other features: Washtec P is available in 8 pot, 16 pot and 24 pot capacities (ISO) Washtec PA2 is available in 8 pot (4+4) 16 pot (8+8) and 24 pot (12+12) capacities (ISO & AATCC) Lid interlock, latch and drive motor safety interlock Filling by touchscreen Industrial quality motor specification Chemical resistant pot seals are available for solvent testing.
FUNCTION
Programming options are simple and easy to input: Push and twist action provides a safe and efficient method of loading/unloading the pots.
System control and temperature calibration accuracy better than +/-1°C.
Temperature control with a +/-0.25°C accuracy Temperature range from ambient 20°C to 98°C.
Touchscreen Controller allowing multiple time, temperature and gradient settings.
TECHNICAL SPECIFICATIONS DIMENSIONS
MODEL (MK4) | LENGTH | DEPTH | HEIGHT |
PA2 4+4 | 625mm | 650mm | 1230mm (Lid Open) P8 |
PA2 8+8 | 850mm | 650mm | 1230mm (Lid Open) P16 |
PA2 12+12 | 1085mm | 650mm | 1230mm (Lid Open) P24 |
VOLTAGE | FREQUENCY |
220-240V | 50/60Hz Single Phase |
400V | 50/60Hz Three Phase & Neutral |